Re: SNMP Performance Cycle
Hi Alex, this is information my system zenoss: Software Component VersionsZenossZenoss 4.2.3OSLinux (x86_64) 2.6.32 (Linux localhost.localdomain 2.6.32-358.18.1.el6.x86_64 #1 SMP Wed Aug 28 17:19:38...
View ArticleRe: Syslog parsing for OSSEC syslog alerts
First I just want to get all the lines. Here's what I currently get in Zenoss:Alert Level: 10; Rule: 18153 - Multiple Windows audit failure events.; Location: (MR51) 192.168.215.51->WinEvtLog;...
View ArticleRe: SNMP Performance Cycle
In Zenoss 4.2.4 snmp collection interval is defined as a property per device, device class if you wish. Check it out.. Device class/Device -> Configuration properties -> zSnmpCollectionInterval...
View ArticleRe: Configuration Properties in Event Classes
You can check "Event count" field. I guess you need a transform for setting a notification related to event durations.. But if you check WMI in a interval of x seconds you can guess how many events...
View ArticleRe: Syslog parsing for OSSEC syslog alerts
James,Here is a start - Just grouped everything as <summary>:(?P<summary>(^Alert Level\:\s\d+.*)\n((.+\n)+)) but you might just want everything after the 192.18.215.51-> in the example...
View ArticleImportError: No module named argparse
New installZenoss Core 4.2.4 using autodeployRan secure_zenoss.sh On first run of Zenoss, receive: Traceback (most recent call last): File "/opt/zenoss/bin/zenpack_batch", line 11, in <module>...
View ArticleRe: IP address goes up and down
Ok I am not getting any outputs when running those commands. Right now Im trying to see if it could be a possible firewall problem or switch problem. Thanks for your help! -Andrew
View ArticleRe: IP address goes up and down
ok!! if not, i think you can run zencommand in debug mode to see which command is using to ping devices and output.. zencommand run -v 10
View ArticleRe: IP address goes up and down
Yea thats how I thought it might be a firewall problem. I ran "zenping run -v10" and some packets were timing out at certain points. zenping is using ICMP.
View ArticleRe: IP address goes up and down
Oh ok! So might need to add and exception for your zenoss server at your firewall. Perhaps it´s tearing down some connection because of a "possible threat".
View ArticleRe: IP address goes up and down
Yea thats what Im thinking. We will see. Thanks for your help. It was much appreciated. -Andrew
View ArticleHandling changing process versions
We have a number of java applications that include information on the version and application name in the arguments. If I use the default process settings, we see process not running events when the...
View ArticleRe: ImportError: No module named argparse
I see another issue. The install stopped at the echo "Securing Zenoss"try su -l -c /opt/zenoss/bin/secure_zenoss.sh zenoss section. With error: Securing ZenossCreating home directory for...
View ArticleRe: IP address goes up and down
It was the least I could do! Hope you solve the problem!
View ArticleSyslog message truncated
Hi, I am running Zenoss Core 4.2.4 on a VM. I notice when I send a syslog message with a carriage return and line feed to zenoss, the message will get truncated at the first carriage return and line...
View ArticleRe: Syslog message truncated
I'm guessing because the "\n" portion causes a line break (or new line),zenoss expects it to be in the normal "syslog standard" which is one line. Take a look at this post, it's not exactly the same...
View ArticleUnable to delete the device from zenoss
Unable to delete the device from Zenoss. Tried in the Zendmd also(device.deleteDevice()). Getting the following log:================================================================2013-12-08T02:22:47...
View ArticleEvent deletion has broken... Again
I was going to clear out all events before I turned this server into production mode, and suddenly Zenoss decides I can't do that. I get this error:ZepConnectionError: Timed out connecting to...
View ArticleRe: SNMP query issues
Not for sure Mike, I had just read the release notes this morning right before you posted. Seems to be related with the same oid being affected.--Rob
View ArticleRe: SNMP query issues
Thanks again for the help. I applied SP179, but ZEN-8868 was not referenced in the details of SP179. Do you have a link to the release notes, I can't seem to locate them.
View Article